AHF (Active Harmonic Filter) 35A/50A/100A/150A/200A IGBT-Based Filter Wall-mounted/Modular AHF Unit

AHF (Active Harmonic Filter) 35A/50A/100A/150A/200A IGBT-Based Filter Wall-mounted/Modular AHF Unit

Rated Voltage Range:200V – 480V (±15%) / 690V High Voltage Version
Grid Frequency:50/60 Hz (±5% Auto-sensing)
Filtering Range:2nd to 50th Harmonics (Individual order selection)
Filtering Degree: Selectable per harmonic order (0–100%)
Filtering Efficiency:≥ 97%
Target Power Factor: Adjustable from -1.0 to +1.0 (Stepless)
Three-Phase Balancing: Yes (Compensates negative and zero sequence current)
Switching Frequency:20 kHz (High-speed SiC/IGBT modulation)
Controller Response Time:< 100 μs (Microseconds)
Full Response Time:< 5 ms (Millisecond total cycle)
Control Algorithm: Intelligent FFT (Fast Fourier Transform) + Instantaneous Reactive Power Theory
Hardware Platform: Dual-core DSP + FPGA (High-speed parallel processing)
CT Requirements:150:5 to 10,000:5 (Class 0.5 or better recommended)
Parallel Connection: Up to 16 modules in a single cabinet
Cooling Method: Intelligent Forced Air Cooling (Variable speed fans)
Noise Level:< 60 dB (Load dependent, optimized airflow design)
Protection Class:IP20 (Standard) / IP31, IP54 (Optional custom enclosures)
Installation: Modular Rack-mount / Wall-mount / Floor-standing
Operating Temp:-10°C to +45°C (No derating)
Display:7-inch Touchscreen
Get a Quote
More Details

Hertzkron Active Harmonic Filters (AHF): The Ultimate Intelligence in Power Quality

1. Hero Section: The Value Proposition

Adaptive. Instant. Absolute. Clean Your Power in Real-Time.

As industrial grids become smarter, they also become more sensitive. Hertzkron Active Harmonic Filters (AHF) utilize cutting-edge 3-level NPC inverter topology to detect and neutralize harmonics instantly. Don't just react to power quality issues—eliminate them with sub-millisecond precision.


2. The Hertzkron Edge: Why Our AHF is the Industry Benchmark

  • Ultra-Fast Real-Time Compensation: Utilizing high-speed DSP (Digital Signal Processing) and FPGA logic, Hertzkron AHFs respond to load changes in less than 1ms, with a full response time of under 5ms. Whether it’s 2nd or 50th order harmonics, our system neutralizes them with up to 98% efficiency.

  • 3-Level NPC Inverter Topology: Unlike traditional 2-level designs, our 3-level Neutral Point Clamped (NPC) architecture significantly reduces switching losses, improves output waveform quality, and extends the lifespan of internal IGBT components. This translates to lower heat generation and higher energy efficiency for your facility.

  • 3-in-1 Comprehensive Solution: Hertzkron AHF is a multi-functional powerhouse. It simultaneously performs Harmonic Mitigation, Stepless Reactive Power Compensation (Leading & Lagging), and Three-Phase Load Balancing, all in one compact modular unit.


3. Solving Modern Power Challenges

Total Compliance with IEEE 519 Standards

Utilities are increasingly enforcing strict THD-i (Total Harmonic Distortion - Current) limits. Hertzkron AHF brings your THD-i down to below 5%, shielding you from grid penalties and ensuring your facility meets the most stringent international regulations.

Eliminate Ghost Trips and Equipment Failures

High harmonic levels cause "phantom" tripping of circuit breakers, overheating of neutral wires, and PLC communication errors. By injecting an equal and opposite compensation current, Hertzkron AHF cleans the sine wave, protecting your sensitive robotics, data centers, and medical imaging equipment.

Dynamic Stepless Compensation

Unlike traditional capacitor banks that switch in steps, our AHF provides stepless, infinitely variable reactive power. This is perfect for environments with rapid load fluctuations, such as welding shops, elevators, or crane operations, where traditional PFC cannot keep up.


4. The Science of Hertzkron Electronics

  • Advanced Thermal Management: Each module features independent high-speed cooling fans and optimized airflow channels to ensure the power electronics stay within optimal temperature ranges even at full load.

  • Intelligent Redundancy: In a modular configuration, if one unit requires maintenance, the remaining modules automatically redistribute the load, ensuring your facility remains protected 24/7.

  • Comprehensive Protection Suite: Built-in safeguards against overvoltage, undervoltage, overcurrent, over-temperature, and short circuits, with a comprehensive fault-log system for easy diagnostics.